Your browser does not support JavaScript! ENDOTHERMIC ATMOSPHERE GENERATOR - SECO/WARWICK

ENDOTHERMIC ATMOSPHERE GENERATOR

Type G-60-ET

 

/ Manufacturer: SECO/WARWICK,
/ Year of production: 2013
/ Location: Poland – Świebodzin
/ Device never used – Customer’s cancelled orders
/ Condition: very good
/ Version without automatic gas flow regulation. Possible upgrade by SECO/WARWICK
/ We offer technical assessment, relocation, and installation of the device at the destination within the EU.

Purpose:

The G-60-ET endothermic atmosphere generator is designed to produce a controlled endothermic atmosphere from natural gas or propane and air. The dew point of the generated atmosphere is within the range of 0°C ± 5°C.

ENDOTHERMIC ATMOSPHERE GENERATOR Type G-60-ET
ENDOTHERMIC ATMOSPHERE GENERATOR

Technical Data

Part Name  Unit Value
Dimensions mm According to assembly drawing
Installed Power kW ~32
Gross Weight kg ~2600
ENDO Atmosphere Output (at free outflow of atmosphere) m3/h 60
Type and quantity of catalyst dm3 5-8%Ni – 30dm3
Process Gas Requirement Nm3/h 5 – propane
13,6 – methane
Calorific Value of Process Gas MJ/m3 35- methan
93 – propane
Nominal Temperature oC 1050
Type of Temperature Sensor   S
Air-Gas Ratio
for propane
for methane
  7,5 do 1v
3,5 do 1

 

 

List of energy factors required to power the generator

Technical Factor Connection Pressure Range Factor Requirement Notes
Cooling Water Supply G1/2” 2-5 Bar 1,2 [m3/h] Temp.<25ºC water hardness:: ≤10°n
Process Gas Supply G 3/4” 150-400 [mbar] 13,6 [Nm3/h]
5 [Nm3/h]
Methane
Propane
Combustion Atmosphere Outlet  Pipe DN50  Free Outlet max.60 [m3/h]  
Heating Element Supply     30 [kW] 3x400V 50Hz
(3x380V 50Hz)
Sample Extraction Point   30-80 [mbar]   Connection – end with inner diameter of 6mm
ENDO Atmosphere Exhaust to Furnace G2“ 30-80 [mbar] 60 [m3/h]  
Flue Gas Extraction     ~1700 [m3/h] Temp. = approx..400oC