Purpose:
The G-60-ET endothermic atmosphere generator is designed to produce a controlled endothermic atmosphere from natural gas or propane and air. The dew point of the generated atmosphere is within the range of 0°C ± 5°C.
Technical Data
Part Name | Unit | Value |
Dimensions | mm | According to assembly drawing |
Installed Power | kW | ~32 |
Gross Weight | kg | ~2600 |
ENDO Atmosphere Output (at free outflow of atmosphere) | m3/h | 60 |
Type and quantity of catalyst | dm3 | 5-8%Ni – 30dm3 |
Process Gas Requirement | Nm3/h | 5 – propane 13,6 – methane |
Calorific Value of Process Gas | MJ/m3 | 35- methan 93 – propane |
Nominal Temperature | oC | 1050 |
Type of Temperature Sensor | S | |
Air-Gas Ratio for propane for methane |
7,5 do 1v 3,5 do 1 |
List of energy factors required to power the generator
Technical Factor | Connection | Pressure Range | Factor Requirement | Notes |
Cooling Water Supply | G1/2” | 2-5 Bar | 1,2 [m3/h] | Temp.<25ºC water hardness:: ≤10°n |
Process Gas Supply | G 3/4” | 150-400 [mbar] | 13,6 [Nm3/h] 5 [Nm3/h] |
Methane Propane |
Combustion Atmosphere Outlet | Pipe DN50 | Free Outlet | max.60 [m3/h] | |
Heating Element Supply | 30 [kW] | 3x400V 50Hz (3x380V 50Hz) |
||
Sample Extraction Point | 30-80 [mbar] | Connection – end with inner diameter of 6mm | ||
ENDO Atmosphere Exhaust to Furnace | G2“ | 30-80 [mbar] | 60 [m3/h] | |
Flue Gas Extraction | ~1700 [m3/h] | Temp. = approx..400oC |